NOTE TO PHYSICIAN: Injection in the skin is a traumatic
injury. It is important to treat the injury surgically as soon as
possible. DO NOT DELAY treatment to research toxicity. Tox-
icity is a concern with some exotic coatings injected directly
into the blood stream. Consultation with a plastic surgeon or
reconstructive hand surgeon may be advisable.
FLUIDS UNDER HIGH PRESSURE FROM SPRAY OR
LEAKS CAN PENETRATE THE SKIN AND CAUSE
EXTREMELY SERIOUS INJURY, INCLUDING THE
NEED FOR AMPUTATION.
NEVER point the spray gun towards anyone or at any part
of the body.
NEVER put hand or ngers over the spray tip. Do not use
rag or other materials over your ngers. Paint will penetrate
through material and into the hand.
NEVER try to stop or deect leaks with your hand or body.
ALWAYS have gun tip guard in place when spraying.
ALWAYS lock gun trigger when you stop spraying.
ALWAYS remove tip from the gun to clean it.
NEVER try to "blow back" paint, its not an air sprayer.
ALWAYS follow the PRESSURE RELIEF PROCEDURE,
as shown on page 9, before cleaning or removing the spray
tip or servicing any system equipment.
Be sure equipment safety devices are operating properly
before each use.
ALWAYS tighten all uid connections before each use.
If any uid appears to penetrate your skin, get
EMERGENCY CARE AT ONCE.
DO NOT TREAT AS A SIMPLE CUT.
• Go to an emergency room immediately.
• Tell the doctor you suspect an injection injury.
• Tell him what kind of material you were spraying with and
have him read NOTE TO PHYSICIAN above.
NEVER alter equipment in any manner.
NEVER smoke while in spraying area.
NEVER spray highly ammable materials.
NEVER use around children.
NEVER allow another person to use sprayer unless he is
thoroughly instructed on its' safe use and given this
operators manual to read.
ALWAYS wear a spray mask, gloves and protective eye
wear while spraying.
ALWAYS ensure re extinquishing equipment is readily
available and properly maintained.
NEVER LEAVE SPRAYER UNATTENDED WITH
PRESSURE IN THE SYSTEM. FOLLOW PRESSURE
RELIEF PROCEDURES ON PAGE 9.
Keep spraying area free from obstructions.
Make sure area has good ventilation to safely remove
vapors. NEVER keep ammable material in spraying area.
NEVER spray in vicinity of open ame or other sources of
ignition. Spraying area must be at least 20 ft. away from
spray unit.
HIGH PRESSURE SPRAY CAN CAUSE EXTREMELY SERIOUS INJURY. OBSERVE ALL
WARNINGS. THIS SPRAYER IS FOR PROFESSIONAL USE ONLY.
ALWAYS set safety lock on the gun in "LOCKED" position
when not in use and before servicing or cleaning.
DO NOT remove or modify any part of gun.
ALWAYS remove spray tip when cleaning.
Flush unit with LOWEST POSSIBLE PRESSURE.
CHECK operation of all gun safety devices before each
use. Be very careful when removing the spray tip or hose
from gun. A plugged line contains uid under pressure. If
the tip or line is plugged, follow the PRESSURE RELIEF
PROCEDURE as outlined on page 9.TIP GUARD
ALWAYS have the tip guard in place on the spray gun
while spraying. The tip guard alerts you to the injection
hazard and helps prevent accidentally placing your ngers
or any part of your body close to the spray tip.
USE EXTREME CAUTION when cleaning or changing
spray tips. If the spray tip clogs while spraying, engage the
gun safety latch immediately.
ALWAYS follow the PRESSURE RELIEF PROCEDURE
before removing the spray tip to clean it.
NEVER wipe off build up around the spray tip.
ALWAYS remove tip & tip guard to clean AFTER pump
is turned off and the pressure is relieved by following the
PRESSURE RELIEF PROCEDURE.
INJECTION HAZARD
ALWAYS INSPECT SPRAYING AREA
WARNINGS CONTINUED ON NEXT PAGE.........
WARNINGS
Keep all labels on the unit clean and readable.
Replacement labels are available from manufacturer.
MEDICAL ALERT - Airless Spray Wounds
If any uid appears to penetrate your skin, get EMERGENCY
MEDICAL CARE AT ONCE. DO NOT TREAT AS A SIMPLE
CUT. Tell the doctor exactly what uid was injected. Have
him read the following "NOTE TO PHYSICIAN".
LABELING
GENERAL PRECAUTION
MEDICAL TREATMENT
SPRAY TIP SAFETY
TIP GUARD
SPRAY GUN SAFETY